RG 6/U-4 CCS/CUSN TRISHIELD HFFR

Place of use

They are used as distribution cables in indoors CATV and CTV systems; and as connection cables in SATV satellite antenna systems where low attenuation is desired. This type of cables is halogen-free, has flame-retarder and low smoke density.

Structure

Inner Conductor

1,02 mmØ  Copper Clad Steel Wire

Insulation

4,60 Ø Physical Foam PE

1.Screen

100 % Coverage Al-Pes Tape

2.Screen

Tinned Copper Wire Braiding, %55 coverage

3.Screen

100 % Coverage Al-Pes Tape

Outer Sheath

7,05 Ø HFFR Compound, RAL 7001 Grey



Product Code Dimension and Weights Electrical Properties
Nominal Cross Section Overall Diemeter
( ~ )
Net Weight
( ~ )
Standart Lenght Max. Dc Conductor Resistance at 20◦ C Current Carrying Capacity
In Ground at 20° C On Air at 30° C

Technical Info

INSULATION 
RESISTANCE
MUTUAL 
CAPACITANCE
VELOCITY OF 
PROPAGATION
OPERATING 
VOLTAGE
TEST 
VOLTAGE
BENDING 
RADIUS
TEMPERATURE 
RANGE
IMPEDANCE
MΩxkm >200053±2 pF/mt82 %1,3 kV3 kV20x D mm-40ºC+70ºC75±3 Ω
FLAME RETARDANT 
TEST 
SMOKE DENSITY 
TEST 
TEST ON CORROSIVENESS 
OF COMBUSTION GASES 
HALOGEN FREE 
TEST 
FLAME PROPOGATION 
TEST 
EC 60332-1-2 
VDE 0482-332-1-2 
EN 60332-1-2 
EC 61034-2 
VDE 0482-1034-2 
EN 61034-2 
IEC 60754-2 
VDE 0482-267-2-3 
EN 50267-2-3 
IEC 60754-1 
VDE 0482-267-2-1 
EN 50267-2-1 
IEC 60332-3-25 
VDE 0482-332-3-25 
EN 60332-3-25  


Catalog Info